A retrospective cohort at Erasmus MC of 453 patients, of which 144 met every inclusion criterion. Liver and spleen volumes were segmented automatically with TotalSegmentator in 3D Slicer, and vessel diameters were measured by hand following a standard protocol, with reproducibility checked between observers.
We built two models side by side: an interpretable linear regression and a tree based XGBoost model. Both were validated with a five by five nested cross validation and compared against a dummy regressor that simply predicts the mean.
The linear model reached a mean absolute error of 2.00 mmHg and met our threshold. But both models explained very little variance and sat close to the baseline. The conclusion was that static anatomical parameters are not sufficient to predict the pressure response after TIPS. What actually drives it, such as intrahepatic resistance, collateral circulation and vessel compliance, is not visible on a CT.
That is a negative result, and it is the part of this project I would defend first. Measuring your model honestly against a baseline and then writing down that it lost is the difference between research and advertising.